CU-SU-711 Infusion sets
CURE I.V. Set
Single-use gravity infusion set with spike, transparent drip chamber, roller clamp, tubing and Luer connector for intravenous fluids.
- Registered with DRAP: MDIR-0001681 (Class B)
- Bulk and distributor pricing on request
- Made in China under the CURE private label
- Reply within [24] hours
Overview
The CURE I.V. Set is a gravity-feed administration set for delivering intravenous fluids from a bag or bottle to a patient’s IV access device. The fluid passes from the spike into a transparent drip chamber, where drops can be counted, and through clear tubing to a Luer connector. A roller clamp on the tubing controls the flow rate.
Key features
- Spike with protective cap to connect to the fluid container
- Transparent drip chamber for monitoring and counting drops
- Roller clamp to start, stop and adjust flow
- Clear, flexible tubing so fluid and air bubbles stay visible
- Luer connector with protective cap for the IV cannula
- Registered with the Drug Regulatory Authority of Pakistan (DRAP)
Applications
- Gravity infusion of intravenous fluids in wards, emergency departments and clinics
- Routine hydration and fluid replacement therapy
Packaging
- Individually packed set [confirm pack type and carton quantity]
| Product code | CU-SU-711 |
|---|---|
| Brand | CURE |
| Product type | Infusion set, gravity feed |
| Category | Infusion sets |
| Sterility | Sterile |
| Use | Single use only |
| Components | Spike with cap, drip chamber, roller clamp, tubing, Luer connector with cap |
| Models | IS-VB1, IS-VB2, IS-VB3, IS-VB4 |
| DRAP registration | MDIR-0001681 (Class B) |
| Shelf life | 5 years |
| Country of origin | China (CURE private label) |
View DRAP registration certificate (PDF)
Full technical data sheet available on request.
How to use
- Check the pack is intact, then close the roller clamp.
- Insert the spike into the fluid container and squeeze the drip chamber to fill it partly.
- Open the clamp to prime the line and expel air, then close it.
- Connect the Luer end to the patient’s IV access device and set the flow with the roller clamp.
- Use for one patient only and dispose of as clinical waste.
Storage
- Store in a cool, dry place away from direct sunlight.
Precautions
- For single use only. Do not re-sterilise or reuse.
- Do not use if the packaging is damaged.
- Make sure the line is fully primed and free of air before connecting to the patient.
- For use by trained healthcare professionals.
Always follow the instructions for use supplied with the product and your facility’s clinical protocols.